63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of AC Switches of W Series

The W Series AC Switches are advanced solid-state switching devices designed for efficient and reliable control of alternating current (AC) loads. These switches offer a combination of high performance, compact design, and ease of integration into various electrical systems. They are engineered to handle significant power levels while minimizing heat generation and electromagnetic interference (EMI). The W Series is suitable for applications requiring precise and rapid control of AC power, such as industrial automation, lighting control, heating systems, and motor drives.

Features of AC Switches of W Series

  1. High Current Capacity: Designed to manage high-power AC loads, ensuring robust performance in demanding environments.
  2. Low Power Loss: Efficient switching mechanism reduces energy consumption and operational costs.
  3. Compact Size: Space-saving design facilitates easy installation and integration into existing systems.
  4. Fast Switching Speed: Enables quick response times, ideal for applications requiring rapid on/off cycles.
  5. Zero-Crossing Detection: Minimizes EMI by turning the switch on or off at zero voltage crossing points.
  6. Overload Protection: Built-in protection mechanisms safeguard against overcurrent and thermal overload conditions.
  7. Wide Operating Temperature Range: Stable performance across a broad temperature spectrum, enhancing reliability.
  8. Long Lifespan: Durable construction ensures long-term operation without frequent maintenance.
  9. User-Friendly Interface: Simple control interfaces make setup and operation straightforward.

63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats

(63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats)

Specification of 63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats

This three-phase automatic transfer switch (ATS) mounts directly on a standard DIN rail inside your electrical panel. It handles power source changes automatically. It switches between the main supply and a backup generator during outages. This ensures critical equipment keeps running without interruption. The switch comes in three common current ratings: 63 Amps, 100 Amps, and 125 Amps. Choose the model matching your specific electrical load requirements.

The switch operates automatically. It constantly monitors the voltage of your primary power source. It detects a failure or significant voltage drop. The ATS instantly disconnects from the failing source. It then sends a signal to start your backup generator. The generator output stabilizes. The switch safely transfers the load to this backup power. The main utility power returns to normal levels. The ATS monitors it. The switch transfers the load back to the main supply. It signals the generator to shut down. This whole process happens quickly and reliably.

Its compact DIN rail design saves valuable panel space. Installation and servicing are straightforward for electricians. Robust construction ensures long-term reliability in demanding environments. Important safety features are built-in. These include mechanical and electrical interlocks. These prevent the dangerous connection of both power sources simultaneously. Isolation barriers enhance operator safety during maintenance.

The switch meets essential electrical safety standards. Look for certifications like CE marking. It operates reliably within a wide voltage range. The typical rated operational voltage is 400V AC. It handles frequent switching operations without performance loss. The design minimizes voltage dips during transfers. This protects sensitive connected equipment. The switch works effectively across standard utility frequencies, usually 50Hz or 60Hz.

63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats

(63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats)

Applications of 63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats

These 63A, 100A, and 125A three-phase DIN rail automatic transfer switches (ATS) are essential for places needing constant power. They automatically switch equipment between the main power supply and a backup generator. This happens fast when the main power fails. The switch senses the problem instantly. It then connects everything to the generator power. This keeps your important systems running without stopping.

Telecom sites and data centers rely heavily on these switches. Power interruptions here cause big problems. Dropped calls, lost data, and network downtime cost money. These ATS units prevent that. They provide a seamless switch to backup power. Critical servers and communication gear stay online.

Small factories and workshops use these ATS switches too. Machines stopping suddenly damages equipment and halts production. It wastes time and materials. Installing this automatic transfer switch protects machinery. Power cuts don’t force a complete shutdown. Production continues using generator power. This saves money and avoids delays.

Retail stores, offices, and medical clinics also benefit. Power loss disrupts point-of-sale systems, computers, and essential lighting. Security systems might fail. Refrigeration for medicines or food can stop. An automatic changeover switch solves this. It ensures vital systems stay powered. Business operations continue smoothly. Patient care or customer service isn’t interrupted.

These DIN rail mounted switches are compact. They fit neatly into standard electrical panels. Installation is straightforward for electricians. The units constantly monitor both power sources. They detect problems like voltage drops or complete loss. Switching happens in milliseconds. The switch automatically returns to mains power once it’s stable and safe. This ensures your primary power source is used whenever possible. It provides reliable, automatic backup power protection for critical three-phase loads.

Company Profile

PDDN Photoelectron Technology Co., Ltd.(sales@pddn.com) is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.

It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats, please send us inquiries; we will be here to help you.


Payment Methods

L/C, T/T, Western Union, Paypal, Credit Card etc.


Shipment

By sea, by air, by express, as customers request.


Storage Conditions

1) Store in a dry environment at room temperature.

2) Avoid damp and high temperature.

3) Use immediately after opening the inner packing bag.

5 FAQs of 63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats

Here are five common questions about the 63A, 100A, 125A Three Phase DIN Rail ATS:

What exactly does this ATS do?
This Automatic Transfer Switch monitors two power sources. Usually this is the mains utility power and a backup generator. The ATS watches the power supply status constantly. If the main power fails, the ATS starts the generator automatically. It switches the connected load over to the generator power. It switches back to mains power when that returns to normal.

Where can I install this transfer switch?
This ATS mounts directly onto standard DIN rail. This is common inside electrical distribution panels or control cabinets. You need a suitable enclosure. The enclosure must protect the switch from dust and moisture. Ensure the enclosure meets local electrical safety standards. The switch needs proper ventilation space around it.

How fast does the switch change power sources?
The switching time is very fast. It typically happens within seconds after detecting a power failure. This speed minimizes disruption to critical equipment. The exact time depends on the generator start-up delay you set. The switch waits for the generator to reach stable voltage and frequency. Then it transfers the load.

What happens if one power source fails during operation?
The ATS continuously monitors both sources. If the active source fails while the load is running, the ATS reacts immediately. It checks the status of the other source. If that source has good power, the ATS switches the load over to it automatically. This protects your equipment from unexpected blackouts.

Does this ATS need regular maintenance?
The unit itself needs minimal routine maintenance. Keep it clean and check electrical connections are tight periodically. Ensure the enclosure remains sealed against environmental factors. The real maintenance focus is on the connected power sources. The mains supply requires standard checks. The backup generator needs its own regular servicing schedule. Test the entire ATS system periodically.

63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats

(63A 100A 125A Three Phase Din Rail Automatic Transfer Switching Ats Transfer Switch Automatic Changeover Switch Ats)

REQUEST A QUOTE

REQUEST A QUOTE